PAS-14 Wet aluminium electrolytic on a product rated for the cold¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-23, NET-24, CFG-2, CFG-7 |
Looks at. The project's minimum ambient, the capacitor's series and its low-temperature impedance ratio.
What it catches. Wet aluminium electrolytic capacitors relied on for filtering, bulk or hold-up on a product whose ambient goes below about −20 °C, when the series' impedance ratio Z(−25 or −40 °C)/Z(20 °C) leaves less than the role needs, or when the project's minimum is below the series' category temperature.
Why it matters. The electrolyte's conductivity falls in the cold: at the series' lowest rated temperature the ESR is 10 to 100 times its room-temperature value (CDE), and below it nothing is specified. A converter's input filter stops filtering, a hold-up capacitor cannot deliver its current, an LDO that needs output ESR in a window leaves it. Polymer and hybrid capacitors change far less.
Example. An outdoor sensor rated −40 °C with a general-purpose 85 °C electrolytic (Z ratio 4 at −25 °C, not specified at −40 °C) as the input bulk of a buck: brown-outs at cold start.
How to check. For wet aluminium capacitors in roles InputCap, OutputCap, InputBulk, Hold, compare the minimum of the board's ambient intent (not run without it) with the series' category minimum and report a ratio above a threshold (default 4) at the lowest specified temperature.
Fix. A low-temperature series, a polymer or hybrid capacitor, or ceramics where the value allows.
References. NIC-AL (impedance ratio, low-temperature behaviour); CDE-AL.