PAS-38 Inductor DCR current sensing without temperature compensation¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-6, NET-7, NET-23, CFG-5 |
Looks at. The controller's sensing method (DCR sensing from its part data and topology), whether an NTC network is present.
What it catches. A converter controller that senses current across the inductor's DC resistance (an RC network across the inductor into CS+ and CS−) without a temperature-compensating NTC network.
Why it matters. Copper's resistance rises about 0.4 %/K (Coilcraft: a 9 mΩ part is 11 mΩ at 85 °C, about 25 % more). The sensed current and the current limit move by the same factor, and an inductor runs 40 to 80 K above ambient at full load: the limit trips early hot, or the over-current protection is set loose to avoid it. DCR tolerance (often ±10 %) adds to it.
Example. A multiphase buck with DCR sensing and no NTC: current balance and the over-current threshold drift with load.
How to check. For regulators whose part data names DCR sensing (or an RC across the inductor into current-sense pins), report when no NTC is in the sense network.
Fix. The NTC network from the controller's datasheet, or a sense resistor.
References. CC469; VI34252.