Skip to content

SER-7 CAN TX and RX crossed between MCU and transceiver

Severity Status Implementation
error planned mid, depends on NET-7, NET-12

Looks at. CAN controller and transceiver pin roles.

What it catches. An MCU's CAN_TX wired to the transceiver's RXD (and CAN_RX to TXD), crossed as if it were a UART.

Why it matters. Unlike UART, the controller and the transceiver are not peers: the transceiver's TXD is an input that takes the controller's TX, its RXD an output to the controller's RX. Crossed, the MCU drives the transceiver's output and listens to nothing; with TXD floating the transceiver sits recessive (its internal pull-up) and the node is silent. Designers used to UART cross them out of habit.

Example. An STM32G0B1 FDCAN1_TX (PB9) to a TCAN1042 RXD pin: two outputs fight on one net, the controller never sees its own frames back and goes bus-off. B153A's SBU modes show how easy this is to get wrong on paper: the mode table on the MCU sheet (SBU1 = FDCAN1_RX, SBU2 = FDCAN1_TX) had to be corrected at the 5 Oct 2026 review.

How to check. Controller pins with CAN TX/RX roles (NET-12) and transceiver pins TXD/RXD (NET-7): TX must meet TXD, RX meet RXD.

Fix. Uncross them. Label the transceiver side CAN_TXD/CAN_RXD with the same names as the controller.

References. TCAN1042H §9.3.5 (floating terminals, TXD pull-up), §9.3.7 (digital inputs and outputs); SLOA101 §5 (Figure 6, node structure).