SER-3 CAN terminator based on MOSFETs or SSRs¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-7, NET-10 |
Looks at. CAN bus lines, termination path through switches.
What it catches. A switchable CAN termination whose switch is a MOSFET pair, an analog switch or a solid-state relay (photo-MOS) in series with the 120 Ω.
Why it matters. The termination sits on the bus lines, which in a fault see the supply wires of the harness (12 V or 24 V; transceivers such as the TCAN1042 are built to survive ±58 V to ±70 V on the bus). A semiconductor switch has to block those in both polarities, its capacitance and leakage load the bus when "off", its on-resistance adds to the 120 Ω and varies with temperature, and its gate drive must reference a node that moves with the CAN common mode. An SSR also has an output capacitance of tens of pF that unbalances the pair. The bus "works on the bench" and fails at the first ground shift or miswire.
Example. B125 and B135 switch their split termination (2 × 60 Ω and a 4.7 nF centre capacitor) with a double-coil latching DPDT signal relay instead (K501, Kemet EE2-5TNUH-L, set and reset coils driven by two FETs): no leakage, no gate drive on the isolated side, and the setting survives power-off. The usual crutch is a pair of BSS138 back-to-back driven from the MCU: the CANL side swings below the FET's source and the body diodes conduct.
How to check. Find a resistor of 100-130 Ω (or a 60 Ω pair) between the CAN lines (pins CANH/CANL of a transceiver, NET-7) whose path passes through a MOSFET, analog switch or SSR (NET-10).
Fix. A signal relay, a solder jumper or a DIP switch; or a CAN transceiver with switchable termination built in. If a semiconductor switch is a must, check its blocking voltage against the transceiver's bus fault rating and its off capacitance against the bit rate.
References. TCAN1042H §10.2.2.1 (CAN Termination); SLOA101 §5 (the CAN bus); ADM3050E features (±40 V bus fault protection); ISO 11898-2:2016.