Skip to content

SER-6 Not the whole bus is connected to a device

Severity Status Implementation
error planned mid, depends on NET-7, NET-12

Looks at. Pin roles per device, bus definitions.

What it catches. A device on a bus with one of its bus pins unconnected or on a different net than the rest of the bus, while the bus itself is complete elsewhere.

Why it matters. It is the per-device side of SER-5: the MCU has MISO, three slaves share it, the fourth slave's SDO pin is left open. The bus works for three devices and the fourth reads 0xFF; nobody suspects the schematic because the bus "works".

Example. An IMU (ICM-42688-P) and a barometer (BMP390) on one SPI bus: the barometer's SDO pin is left open because on the breakout board it was the I2C address strap, so in SPI mode its data never reaches MISO.

How to check. For each device with bus pins (NET-7), its role pins must reach the bus nets (directly or through series parts, NET-10); a role pin that is unconnected or on its own net is the finding.

Fix. Wire the missing pin; for dual-mode parts (I2C/SPI) check the pin names for the mode used.

References. Wikipedia, Serial Peripheral Interface "Multidrop configuration".