SER-23 RS-485 or CAN node without a proper ground reference

Severity Status Implementation
warning planned hard, depends on NET-5

Looks at. Ground structure, isolation barrier, connector ground pins.

What it catches. An RS-485 or CAN node whose bus connector carries no ground (and the node is not isolated), or whose signal ground is tied straight to the bus ground wire so the cable closes a ground loop.

Why it matters. The transceivers are differential, but only within a common-mode range (RS-485 −7 to +12 V, CAN roughly −2 to +7 V for classic parts). Remote nodes powered from different parts of an installation can sit volts apart; without a ground wire the common mode drifts out of range, with a hard ground wire the potential difference drives current through the cable shield and signal ground. TI's guide shows both pitfalls and recommends a resistor-separated ground (100 Ω) or, better, an isolated node.

Example. B125 and B135 isolate each CAN channel: an ADM3050E (5.7 kV rms signal isolation) with an isolated B0505MT DC-DC for the bus side. On B135 the DE-9 ground pins (3, 6) reach only the isolated ground, the shell goes to it through 1 nF or a solder jumper, and a Y-rated capacitor (C508) bridges the barrier for EMC. The failure case is a non-isolated RS-485 node with the DE-9 pin 5 tied to the board's GND and the board's GND tied to protective earth at the other end too.

How to check. For each transceiver's bus side, find its ground net (NET-5); recognise an isolation barrier (isolated transceiver, isolated DC-DC) between it and the logic ground; check whether the connector carries that ground and how (direct, through a resistor). Whether the far side is grounded is outside the netlist.

Fix. An isolated transceiver with an isolated supply (best); otherwise a ground wire through a ~100 Ω resistor, and a shield to chassis at one end.

References. SLLA272 §11 (Grounding and Isolation, Figure 11-1); ADM3050E features and "Applications Information"; SLLA070 §2.2.5 (−7 V to 12 V); SLLA337 §2 (ground shift); SLOA101 §5.1.3 (common-mode range).