SER-14 CAN split termination without the centre capacitor

Severity Status Implementation
warning runs in better_erc easy, depends on netlist

Data it needs: graph, part classes, values, rails.

Looks at. Resistor pair between the CAN lines, capacitor to ground.

What it catches. Two resistors of ~60 Ω in series between CANH and CANL whose middle node has no capacitor to ground (or goes to a transceiver's SPLIT pin without one).

Why it matters. Split termination exists to give the common-mode noise a low-impedance path to ground at high frequency through the centre capacitor (typically 4.7 nF). Without the capacitor the pair is just a 120 Ω termination with an extra part, and the designer believes the EMC problem was handled. The two halves also need matched tolerance (1 %) or common-mode noise is converted into differential noise.

Example. B125 (2 × 60.4 Ω) and B135 (R506/R507, 2 × 60 Ω) put a 4n7 (C515 on B135) from the centre to the isolated ground, the textbook form. The usual mistake is a DNP centre capacitor kept from an EMC experiment, or a value of 100 nF that loads the common-mode at the bit rate.

How to check. A series pair of resistors, each 50-70 Ω, between two nets that reach one transceiver's CANH and CANL; the centre net must have a capacitor (fitted in this variant) to a ground.

Fix. Add 4.7 nF (1-10 nF, rated for the bus fault voltage) from the centre to ground, or to the transceiver's SPLIT pin; 1 % resistors.

References. SLOA101 §5 (Figure 12, CL 4.7 nF, ±1 % resistors); SLLA337 §2 (Figure 2-5, split termination under ground shift); TCAN1042H §10.2.2.1 (Figure 10-2).

Settings

Set them in the project file under [checks."SER-14"], or for one run with --set SER-14.NAME=VALUE.

Setting Default Meaning
SER-14.min_half 50 ohm lower end of one half of a split termination
SER-14.max_half 70 ohm upper end of one half of a split termination

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only SER-14 reports on it.

ser-14_can_split_termination

The test schematic ser-14_can_split_termination The test schematic ser-14_can_split_termination

  warning    SER-14 #fdm    CAN split termination R1 (60 Ω) and R2 (60 Ω) has no capacitor from its centre /CAN1_SPLIT to ground: common-mode noise has no path and it is a plain 120 Ω
                            net /CAN1_SPLIT, part R1, part R2
                            fix: 4.7 nF (1-10 nF, rated for the bus fault voltage) from the centre to ground or to the transceiver's SPLIT pin; 1 % resistors
  warning    SER-14 #064    CAN split termination R5 (62 Ω) and R6 (62 Ω) has no capacitor from its centre /CAN3_SPLIT to ground: common-mode noise has no path and it is a plain 120 Ω
                            net /CAN3_SPLIT, part R5, part R6
                            fix: 4.7 nF (1-10 nF, rated for the bus fault voltage) from the centre to ground or to the transceiver's SPLIT pin; 1 % resistors