Skip to content

SER-4 LVDS without terminators

Severity Status Implementation
error planned mid, depends on NET-7, IMP-10

Looks at. LVDS pairs, receiver pins and their on-die termination.

What it catches. An LVDS pair (or sub-LVDS, M-LVDS, LVDS clock) with no 100 Ω differential termination at the receiver end, neither a resistor nor an enabled on-die terminator.

Why it matters. An LVDS driver is a current source of about 3.5 mA; the termination resistor turns it into the ±350 mV the receiver sees. Without it the current has no defined return, the line voltage floats up to the driver's compliance limit and the far end reflects every edge. Some designs "work" at low rates from the receiver's input capacitance, then fail with temperature or a longer cable.

Example. An FPGA (Artix-7, HR bank) receiving an LVDS camera link: the designer assumed DIFF_TERM would be set in the constraints, the firmware team did not set it, and the board has no 100 Ω footprint to fall back on. TI's design note states it plainly: termination at the far end of the interconnect is mandatory.

How to check. Find differential pairs driven by LVDS outputs or reaching LVDS inputs (pin data, NET-7; FPGA bank and pin standards, IMP-10); look for a ~100 Ω resistor across the pair at the receiver. An FPGA input with optional internal termination needs a project setting saying it is enabled (CFG-2).

Fix. A 100 Ω resistor across the pair, as close to the receiver pins as possible (fly-by when the receiver is more than ~2 cm away), or the receiver's internal termination, documented on the sheet. Never at the driver.

References. SLLA014 "Termination" (mandatory, 100 Ω, Figure 4) and "Stubs" (fly-by, Figure 5); HSDD chapter 6; Wikipedia, LVDS.