Skip to content

SER-17 Transceiver logic side on a different rail than the MCU pins

Severity Status Implementation
error planned mid, depends on NET-5, NET-7

Looks at. Transceiver VIO pin, MCU IO bank supplies, power structure.

What it catches. A transceiver (CAN, RS-485, RS-232, Ethernet PHY strap side) whose logic supply (VIO, VL, VCC1) is on a different rail than the MCU bank its TXD/RXD pins talk to.

Why it matters. The logic supply sets the RXD output high and the TXD input thresholds. VIO at 5 V drives 5 V into a 3.3 V pin that may not be 5 V tolerant, and backfeeds the MCU rail through its clamp diodes; VIO at 1.8 V next to a 3.3 V MCU gives RXD highs below the MCU's VIH. A 5 V-only transceiver without VIO has TTL inputs (3.3 V in is fine) but drives RXD to 5 V.

Example. A TCAN1042HV with VIO tied to the 5 V CAN supply because "the V means 5 V", talking to an STM32H7 on a pin that is not 5 V tolerant: RXD drives 5 V into the MCU. TI notes that the non-V variants drive RXD to VCC, so they need a 5 V tolerant input.

How to check. For each transceiver logic pin (NET-7), take the rail of its VIO pin (or its VCC if it has none) and the rail of the bank of the MCU pin on the same net (NET-5); differing rails are the finding, unless a translator sits between them (NET-10).

Fix. VIO from the MCU's IO rail; a transceiver with a VIO pin when the bus supply differs from the logic.

References. TCAN1042H §9.3.7 (Digital Inputs and Outputs, VCC-only and VIO variants); SLLA337 §1.