PIN-10 Polyfuse hold current below the load, or its resistance in an accurate supply¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on CFG-2, RPT-2 |
Looks at. Polyfuse hold current and resistance from the MPN, the load current, the rail's tolerance.
What it catches. A polymeric PTC whose hold current is below the current the load draws in normal operation, or whose resistance (which rises after each trip) sits in series with a rail that has to be accurate.
Why it matters. The hold current is the highest current at which the PTC is guaranteed not to trip, at 25 °C; it falls with temperature. Above it the PTC trips during normal use and the load browns out. Its resistance is not small (ohms for 100 mA parts) and after a trip it settles higher than new, so a PTC in front of a sensor supply or an ADC reference adds a load-dependent error.
Example. B200A J102 pin 1 +3V3_OUT goes through F102, a 100 mA hold, 300 mA trip polyfuse. An adapter card drawing 120 mA works at the bench and trips after a few minutes in a warm enclosure; one drawing 80 mA sees the 3.3 V output sag by the PTC's resistance times its current.
How to check. The load per output from the project or a consumption report (CFG-2, RPT-2) against the hold current, rerated for the ambient temperature; for rails the project marks as accurate, flag any PTC in series.
Fix. A PTC with a hold current above the worst-case load at the hottest ambient, or an eFuse whose current limit is accurate and whose on-resistance is milliohms.
References. Fuseology "PTC Characteristics and Terms" (hold and trip current, rerating with temperature); Wikipedia, Resettable fuse (hold current, resistance after a trip); SLVA862A §1 (PTC resistance after resets).