Skip to content

PIN-12 Two power sources on one net without ORing

Severity Status Implementation
error planned mid, depends on NET-5, NET-7

Looks at. Power sources (connectors, batteries, regulator outputs) and what joins them.

What it catches. A net fed from two sources (battery and USB, two connectors, two regulator outputs) that are joined directly, without ORing diodes, an ideal-diode controller, a power multiplexer or a switch.

Why it matters. Two sources tied together are never at exactly the same voltage: the higher one drives current into the lower. USB VBUS pushed into a battery charges it with no control; one supply pushed into another's output drives it backwards; a host's VBUS pushed into a second host's port is a USB compliance failure and can damage either.

Example. B153A runs from either of two VBUS (receptacle and plug) and does it right: +VIN_SUM is +V1 through D801 or +V2 through D802, both 1N5819W Schottkys, so neither port ever feeds the other. Drop the diodes and the computer's VBUS is wired straight to the device under test's VBUS.

How to check. Find the sources on each rail (NET-5: connector inputs, battery terminals, regulator outputs) and follow from each to the shared net; the path must contain a diode in the forward direction, a part the library classes as ideal diode, power mux or load switch (NET-7), or end at a controlled switch.

Fix. Schottky diodes for small currents (as on B153A), an ideal-diode controller (LM74700-Q1, LM5050) or a power-mux IC where the drop matters, a charger with power path for battery plus external supply (BAT-3).

References. SLVAE57 §3 (ORing power supplies), §8 (ORing with ideal-diode controllers); LM74700-Q1 §10.2 (OR-ing application configuration); RAIL-18 for two regulator outputs.