PIN-2 Fast blow fuse where inrush is expected

Severity Status Implementation
warning planned mid, depends on NET-5, RPT-1

Looks at. Fuse type (fast-acting or time-lag) from the MPN, the capacitance and loads behind it.

What it catches. A fast-acting or very-fast-acting fuse ahead of a load that draws a large current pulse in normal operation: bulk capacitance charged on plug-in, a motor start, a hot-plugged downstream board.

Why it matters. A fuse opens on the energy it absorbs (I²t), not on the current alone. A fast fuse sized for the steady current melts on a few milliseconds of inrush, or survives it partly melted and opens weeks later after enough plug cycles: a nuisance trip that looks like a random field failure.

Example. A 1 A very-fast-acting chip fuse on a hot-plugged 24 V input followed by 2 × 220 µF. Only the cable and the capacitors' ESR limit the plug-in current: tens of amperes for a few hundred microseconds, an I²t in the range of the fuse's own melting I²t.

How to check. Identify the fuse type from the MPN or the library (fast, very fast, time-lag); sum the capacitance downstream up to the next switch or regulator with soft start (RPT-1); flag a fast fuse with more than a project threshold of bulk capacitance or a motor, relay or connector-to-another-board load behind it.

Fix. A time-lag (Slo-Blo) fuse whose I²t covers the inrush pulse with margin, a soft-start or inrush limiter in front of the bulk capacitance (SEQ-6), or an eFuse with a set inrush slew.

References. Fuseology "Selection Factors" 6 (pulses, surge, inrush and start-up currents) and "Pulses" with the I²t worked example; SLVA862A §1 (fuse blowup during inrush), §3.1 (inrush current control).