PIN-9 TVS clamping voltage above the absolute maximum of what it protects¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-5, NET-7 |
Looks at. TVS clamping voltage from the MPN, absolute maximum of the parts on the protected rail.
What it catches. A TVS whose clamping voltage VC at its rated pulse current is above the absolute maximum input voltage of the regulator or IC it sits in front of.
Why it matters. VC is far above VR: an SMF22A has VR 22 V but clamps at 35.5 V at its 5.6 A rated pulse. The TVS only limits the spike to VC; if the part behind it is rated for less, the part breaks down first and the TVS protects nothing.
Example. B200A's VBUS TVS D1605 carries the symbol SMF22A while its value says SMF5V0A. If the SMF22A is what gets fitted, it clamps at up to 35.5 V in front of the RT5760 buck, which the review notes rate at 6.5 V absolute maximum. The SMF5.0A (VC 9.2 V) is the right family member for a 5 V-only input, and still above 6.5 V at full pulse current: the review note "fine for 5 V only" holds only for pulses well below the rated Ipp.
How to check. For each TVS on a rail (NET-5): VC from the MPN; the lowest absolute maximum of the input pins on the same rail up to the next series element (NET-7). Flag VC above that.
Fix. A TVS with a lower VC (often the lower VR is impossible because of PIN-8, which leaves a higher-power TVS with a flatter clamp), a series element that limits the pulse current (ferrite, resistor, PTC), a regulator with a higher input rating, or an active OVP switch.
References. SMF datasheet, Electrical Characteristics table (VC at Ipp, 10/1000 µs); LM74700-Q1 §10.1.1.3; SLVA862A §3.5 (output voltage clamp during transient overvoltage).