PIN-11 Fuse or polyfuse rated above the connector, cable or trace it protects

Severity Status Implementation
warning planned mid, depends on CFG-2

Looks at. Fuse rating, connector contact rating, cable and trace current capacity.

What it catches. A fuse whose rating is above the current the connector contacts, the cable or the trace behind it can carry.

Why it matters. A fuse protects the wiring, not the load. If it is rated above the weakest conductor in its path, an overload just below the fuse's opening current heats that conductor instead: a header's contacts discolour and loosen, a thin trace delaminates, a cable's insulation softens, and the fuse never notices.

Example. A 3 A fuse feeding an output on a 2.54 mm pin header whose contacts the datasheet rates at 1 A: a 2 A overload on that output runs for hours, well under the fuse's opening current and twice the contact rating.

How to check. Fuse rating from the MPN against the contact rating of connectors on the same path (library data) and cable or trace limits from the project (CFG-2); the trace part needs layout data and stays a report item until then.

Fix. A fuse rated at or below the weakest conductor, or a heavier connector and cable. Size traces with IPC-2152 (by title: Standard for Determining Current Carrying Capacity in Printed Board Design).

References. Fuseology "Selection Factors" 1 and 4; Wikipedia, Fuse (electrical); IPC-2152.