PIN-7 Fuse rating vs the expected current¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on NET-8, RPT-2, CFG-2 |
Looks at. Fuse rating and curve from the MPN, the worst-case normal load, the fault current.
What it catches. A fuse that does not sit between the two currents it has to tell apart: rated so low that the worst-case normal load (all loads on, hot, low input voltage, inrush) ages or blows it, or so high that the fault it is there for (a shorted output, a shorted cable) does not open it in time.
Why it matters. Fuses are derated: a fuse carries about 75 % of its rating indefinitely at 25 °C and less when hot. Above that it runs hot and fails early; far above the fault current it never opens and the cable becomes the fuse. The right value comes from two currents, both of which the designer has to know.
Example. On B135B the bring-up list has "fuse: blows when it has to, doesn't blow in the worst-case connection" as an open check for rev C: the value was chosen without both currents written down. A 1 A fuse ahead of a board that draws 0.8 A at the minimum input voltage has no margin (1 A × 0.75 = 0.75 A).
How to check. Needs the worst-case load per input from the power states (NET-8, RPT-2) or the project (CFG-2), the fuse rating and derating from the MPN, and the available fault current (source limit, cable resistance). Report both margins.
Fix. Rating ≥ worst-case normal current / (0.75 × temperature rerating), and an opening time at the expected fault current short enough for the cable and connector (PIN-11).
References. Fuseology "Selection Factors" 1 (normal operating current, 25 % derating), 3 (ambient temperature), 4 and 5 (overload and maximum fault current); B135B rev C change list.