Skip to content

PIN-17 PMOS reverse-polarity switch beyond Vgs(max), or not fully on at low input

Severity Status Implementation
error planned mid, depends on NET-5, NET-7

Looks at. The PMOS gate network, Vgs(max), threshold and Rds(on) conditions from the MPN, the input voltage.

What it catches. A PMOS reverse-polarity switch whose gate is pulled to ground on an input above the FET's maximum gate-source voltage, with no zener from gate to source and no divider; or, on an input of 5 V or less, a standard-threshold FET that the available gate voltage never turns fully on. ≈ DRV-10.

Why it matters. With the gate tied to ground, Vgs equals the input voltage. Above Vgs(max) the gate oxide breaks down, usually the first time the input spikes, and the FET fails short (or open). At low input the opposite fails: a FET specified at Vgs = −10 V carries the load on its body diode or in its linear region, drops a volt and overheats.

Example. An AO3401A (VDS −30 V, VGS ±12 V) as reverse protection on a 24 V input with its gate to ground through 10 kΩ sees −24 V on the gate. On a 3.3 V input, a PMOS whose Rds(on) is given only at −10 V and whose threshold can be −4 V never fully conducts; the same AO3401A is specified down to −2.5 V and is the right choice there.

How to check. For a PMOS in an input path (NET-5) with its drain towards the connector: follow the gate network; compute the worst-case Vgs from the input maximum and any divider or zener; compare with Vgs(max) from the MPN (NET-7). At low inputs compare the minimum input with the Vgs at which Rds(on) is specified.

Fix. A zener from gate to source (10-12 V for a ±20 V FET, lower for ±12 V) with a gate resistor, or a gate divider; at low inputs a logic-level FET with Rds(on) specified at 2.5 V or less, or an ideal-diode controller with a charge pump.

References. SLVA862A §3.8 (P-MOSFET with Zener diode and resistor, Figure 14(b)); SLVAE57 §4.1; AO3401A datasheet, Alpha & Omega (absolute maximum ratings, RDS(ON) conditions) aosmd.com.