PIN-5 No overvoltage protection on a power input¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-5, NET-7 |
Looks at. Power inputs, TVS and clamp parts identified from the MPN or library.
What it catches. A power input without a TVS, clamp or overvoltage-protection switch near the connector.
Why it matters. Inputs see more than their nominal voltage: inductive spikes when a cable is unplugged under load, hot-plug ringing (PIN-14), a wrong adapter, ESD, automotive load dump. The regulator behind the connector is usually rated with little margin above the highest normal input, and its silicon fails on the first spike over its absolute maximum.
Example. A 12 V vehicle input straight into a 40 V buck: an unsuppressed load dump (ISO 16750-2) rises far above 40 V for hundreds of milliseconds and destroys it. On B153A and B200A, VBUS has an SMF-series TVS at the receptacle; the cases where its values are wrong are PIN-8 and PIN-9.
How to check. On each input (NET-5), look for a part the library classes as TVS, zener clamp or OVP switch from the input net to ground before the first regulator. A plain diode or zener needs the MPN to tell it from a TVS, so this needs the part class, not just the D designator.
Fix. A TVS whose standoff is above the input's maximum and whose clamp is below the protected part's absolute maximum (PIN-8, PIN-9); for slow overvoltage (a wrong adapter) an OVP switch or eFuse that disconnects.
References. SLVA862A §3.5 (overvoltage protection), §3.9 (surge protection); LM74700-Q1 §10.1.1.3 (selection of TVS diodes for 12 V battery protection); Wikipedia, Transient-voltage-suppression diode; ISO 7637-2 (road vehicles, electrical transient conduction along supply lines) and ISO 16750-2 (road vehicles, electrical loads: load dump), by title.