PIN-14 No bulk capacitance where a supply arrives through a long cable or is hot-plugged¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on CFG-2, RPT-1 |
Looks at. Inputs marked as cable-fed or hot-plugged, capacitance on them.
What it catches. An input fed through a long cable or plugged in live that has only low-ESR ceramic capacitors on it, no bulk capacitor with some series resistance.
Why it matters. The cable's inductance and a ceramic capacitor form an almost undamped LC circuit. When the plug makes contact the voltage overshoots: up to twice the source voltage. A 24 V supply then puts close to 48 V on a regulator rated for 40 V. Nothing in the steady state shows it; the first hot plug does.
Example. A board fed with 24 V over 2 m of cable with 2 × 4.7 µF ceramics at a 40 V buck: the plug-in spike can approach 48 V. An aluminium electrolytic of 47 µF across the input damps it to a clean rise.
How to check. Which inputs are cable-fed or hot-plugged is a project fact (CFG-2, or connector class from the library); sum the capacitance on the input and check that at least one part has ESR in the damping range (electrolytic, polymer, or a ceramic with a series resistor) (RPT-1).
Fix. A bulk electrolytic or polymer capacitor at the input, an RC snubber, a TVS (PIN-5), or an inrush limiter that ramps the input.
References. AN88 (spikes twice the input voltage, damping with a high-ESR capacitor, comparison of snubbers); SLVA862A §3.9 (surge protection).