Skip to content

RATE-11 Supply pin voltage outside the part's range

Severity Status Implementation
error planned mid, depends on NET-5, NET-7, CFG-5

Looks at. Rail voltage per supply pin, the part's operating range and absolute maximum per supply pin.

What it catches. A part whose supply pin sits on a rail outside its operating range (it may not work) or above its absolute maximum (it gets damaged): a 3.3 V rail into a 1.8 V-only part, a 5 V rail into a 3.6 V-maximum part.

Why it matters. It is one of the most basic errors, and still common, because the netlist does not carry voltages and the part's range lives in its datasheet. It hides in parts with many variants (the same flash in 1.8 V and 3.3 V versions), in nets whose names do not tell the truth, and in reused blocks moved to a board with different rails.

Example. B153A and B200A both have a "1V8" LDO that is a TLV70233, a fixed 3.3 V part: the +1V8_LDO net is really about 3.2 V. On B153A it is the low option of the voltage for the target's SBU lines, so a 1.8 V target would see 3.2 V. On B200A the flash is a 2.7-3.6 V part on 3.3 V, correct, but its BOM datasheet link points at the 1.8 V variant: a check reading that range would have flagged it, and a buyer following the link could order a part that 3.3 V would destroy.

How to check. For each supply pin (NET-7 roles), take the rail's voltage range (project or name) and compare it with the operating range and absolute maximum of that pin from the part data. Use the regulator's real output (from its MPN) rather than the net name where they differ (NAME-8).

Fix. The right part variant or the right rail; fix the regulator (TLV70218 for 1.8 V in the B153 and B200 rev B change lists).

References. B153A and B200A schematic review notes (TLV70233 on +1V8_LDO, flash datasheet link); B153 and B200 rev B change lists.