Skip to content

RATE-3 Shunt power ratings

Severity Status Implementation
warning planned mid, depends on CFG-2, CFG-5

Looks at. Shunt value, maximum current in its path, its power rating.

What it catches. A current-sense shunt whose I²R at the maximum current (including fault current up to the limit or fuse) exceeds its rating.

Why it matters. Shunts carry the full load current and sit in the power path; an overloaded shunt drifts with temperature (so the measurement drifts), heats the board under the sense amplifier, and fails open, which removes the load's path or the ground reference. The fault current matters: a shunt in front of a current limiter carries the limit, not the nominal load.

Example. A 10 mΩ shunt in a 1206 package rated 0.5 W in an 8 A path: 0.64 W, over the rating at room temperature already; at a 10 A fault limit it is 1 W. A 2512 shunt rated 1 W or more, or 5 mΩ with more amplifier gain (ANA-15), fixes it.

How to check. Recognise shunts (low-value resistors in a power path, connected to a sense amplifier's inputs); take the maximum current of the path from the project (or the limit of the current limiter or fuse in series) and compare I²R with the rating from the MPN, derated for temperature.

Fix. A larger or higher-rated shunt, a lower value with more gain, or a shunt with Kelvin terminals in a package meant for power.

References. TI INA181 datasheet (SBOS793H) §8.1.2 "RSENSE and Device Gain Selection" (ti.com/lit/ds/symlink/ina181); Vishay thin film chip resistor datasheet (derating).