RATE-31 Capacitors in series without voltage balancing

Severity Status Implementation
warning planned mid, depends on NET-5, CFG-5, CFG-7

Looks at. A series string of capacitors (supercapacitors, electrolytics), the total voltage, each part's rating, balancing parts across each.

What it catches. Two or more supercapacitors or electrolytic capacitors in series across a voltage higher than one can take, without balancing resistors (or an active balancer) across each, or with balancing resistors too large for the parts' leakage.

Why it matters. In DC steady state the voltage divides by leakage, not capacitance, and leakage of supercapacitors and electrolytics varies widely: the cell with the least leakage takes most of the voltage and is overstressed. Eaton: with ±20 % cells on a 5 V supply, one cell sees 3 V, its surge rating; balancing resistors should draw at least 50 times the worst-case leakage (3.3 to 22 kΩ for their cells), or use active balancing.

Example. Two 2.7 V supercapacitors in series on a 5 V hold-up rail with no resistors across them.

How to check. Find series strings of capacitors (a net with exactly two capacitor pins and nothing else, repeated), compare the string's voltage with the sum of ratings and each part's share without balancing, and check for a resistor or balancing IC across each with a current at least 50 times the parts' leakage.

Fix. Balancing resistors across each part, an active balancer, or parts rated for the full voltage.

References. Keys of the PAS page reference list: EAT-SC.