Skip to content

RATE-18 Relay, solenoid or motor current above its driver's rating

Severity Status Implementation
warning planned mid, depends on CFG-5, CFG-2, NET-10

Looks at. The load's current (coil resistance and voltage, or project data), the driver's rating, the path from driver to load.

What it catches. An inductive or high-current load (relay coil, solenoid, motor) driven by something rated for less: a GPIO driving a relay coil directly, a small BJT below the coil current, a driver channel over its per-channel or package rating.

Why it matters. The driver overheats or fails, often slowly: a GPIO driving 70 mA works on the bench and fails in the field. Motors draw several times their running current at start and stall, and a driver sized for running current fails at the first blocked rotor.

Example. A 5 V relay with a 70 Ω coil (about 71 mA) on an MCU pin rated around 20 mA: the pin's output sags, the relay may not pull in, and the MCU's IO structure is stressed. A ULN2003A channel (500 mA peak per output) handles it, but seven channels at 300 mA together exceed what the package can dissipate.

How to check. Follow the load back to its driver (NET-10: through series resistors and transistors); compute the load current from the coil resistance and supply or take it from the project; compare with the driver's rating from the part data (GPIO from NET-7, transistor Ic, driver channel and package totals).

Fix. A transistor or driver rated for the current (with a freewheeling diode for inductive loads), parallel channels where the driver allows, or a load that draws less.

References. TI ULN200x datasheet (SLRS027T): 500 mA per output, package dissipation (ti.com/lit/ds/symlink/uln2003a); AoE3 chapter 2 (BJT switches with inductive loads).