Skip to content

RATE-4 MOSFET Vds rating

Severity Status Implementation
warning planned mid, depends on NET-5, CFG-5, LIB-3

Looks at. Drain and source nets and their voltages, the MOSFET's Vds rating.

What it catches. A MOSFET whose maximum drain-source voltage is below, or too close to, the highest voltage it must block between drain and source.

Why it matters. Above Vds(max) the FET avalanches: it may survive a few events, then fails short, which for a power switch means the load is always on or the supply is shorted. Inductive loads and hot-plugged inputs add spikes above the steady voltage. Load switches on USB-C VBUS must block whatever the port can negotiate.

Example. On B153A the switch Q102 that puts the receptacle VBUS on header pin 10 is an SLMT330V3CP in the BOM (the value field says SSM3J35); VBUS can be 20 V after PD negotiation, and the schematic review flagged its Vds rating against 20 V as a point to check.

How to check. With the pins named (LIB-3), take the voltages of the drain and source nets (rails, or the project's range for the net) and compare the largest difference with the Vds rating from the MPN; report margins below a set ratio (for example 1.2 for resistive loads, more for inductive ones).

Fix. A FET with a higher Vds rating; a clamp (TVS, snubber, freewheeling diode) for inductive spikes.

References. B153A schematic review notes (Q102, Vds for 20 V); Wikipedia, USB hardware "USB Power Delivery" (fixed supplies up to 20 V); AoE3 chapter 3 (FETs).