RATE-20 Bus termination resistors not rated for a bus fault¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on CFG-2, CFG-5 |
Looks at. Termination resistors on bus nets, the fault voltage the bus can see, the resistor's power rating.
What it catches. RS-485 or CAN termination resistors (120 Ω, or 2 × 60 Ω split) sized for normal operation only, which a bus line shorted to the supply would overload.
Why it matters. In normal operation a termination resistor sees a few volts and a few tens of milliwatts, so 0402 or 0603 parts look fine. Field buses run next to 12 V or 24 V supply wires; a miswire or a crushed cable shorts a bus line to the supply, and the resistor then carries the transceiver's short-circuit current with the supply voltage across it, watts for as long as the fault lasts. The transceiver may be rated to survive that; the resistor burns, the node stays off the bus or the board chars.
Example. On B125A the 120 Ω termination R77 was soldered for the PoE setup (assembly report), and the rev B change list asks for a higher power rating for the termination resistor. TI's CAN guide puts it plainly: a bus-line short to a 24 V supply drives the transceiver's short-circuit current through the termination, and a ¼ W resistor "would blow up in this circumstance".
How to check. Recognise terminations (a resistor of about 120 Ω or two of about 60 Ω across a differential pair at a transceiver); take the fault voltage from the project (the highest supply in the same cable) and the transceiver's short-circuit current from its part data; compare V × I, or V² / R, with the resistor's rating.
Fix. A termination in a package rated for the fault (often a 2010 or 2512 part), split termination with two larger resistors, or a bus-fault-protected transceiver with a fused or switched termination.
References. TI SLLA270, Controller Area Network Physical Layer Requirements, §4.5 "Line Terminations" (ti.com/lit/an/slla270); TI SLLA272, The RS-485 Design Guide, Rev. D, §6 "Bus Termination and Stub Length" (ti.com/lit/an/slla272); B125 rev B change list.