RATE-26 Electrolytic capacitor lifetime at the board's temperature below the product's life¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on CFG-2, CFG-5, CFG-7, RPT-3, RPT-26 |
Looks at. The series' rated life and temperature, its ripple current, the board's ambient and life_years intents.
What it catches. Wet aluminium, polymer and hybrid electrolytic capacitors whose expected life at their core temperature (the board's ambient plus ripple self-heating) is shorter than the life the board's intent states.
Why it matters. Electrolytics wear out: the electrolyte dries through the seal, capacitance falls and ESR rises (CDE: it doubles by the end of life). Wet aluminium life doubles for every 10 K below the rated temperature and halves for every 10 K above (Nichicon, Würth SN008); polymer and OS-CON life grows tenfold per 20 K (Vishay 90017). A 2000 h at 105 °C part at a 75 °C core lasts about 16000 h, under two years of continuous operation.
Example. A 24/7 industrial controller rated for 10 years at 60 °C ambient with 85 °C 1000 h electrolytics on its 24 V input.
How to check. For each electrolytic, take the core temperature (project ambient plus the ripple self-heating from RATE-25's current and the series' ripple rating), compute the life (L0 × 2^((T0 − T)/10) for wet, L0 × 10^((T0 − T)/20) for polymer and hybrid, capped as the vendor caps it), and compare with the board's life_years and duty (not run on a board whose intent states no ambient or life).
Fix. A higher temperature or long-life series, a polymer or hybrid capacitor, ceramics, or less ripple and heat.
References. Keys of the PAS page reference list: NIC-AL; CDE-AL; VIS-OSCON; WE-SN008 (Würth Elektronik SN008, Expected Lifetime of Aluminum Electrolytic and Aluminum Polymer Capacitor, we-online.com); EAT-SC for supercapacitors.