Skip to content

RATE-14 TVS clamp above the protected pin's maximum

Severity Status Implementation
warning planned mid, depends on NET-7, CFG-5

Looks at. The TVS's clamping voltage, the absolute maximum of the pins on the protected net.

What it catches. A TVS diode whose clamping voltage at the expected surge current is above the absolute maximum of the parts it is meant to protect.

Why it matters. A TVS does not hold the line at its standoff voltage: it starts conducting at its breakdown voltage and, at the surge current, clamps at a voltage well above it. If that is higher than the protected pins can stand, the TVS conducts, and the IC fails anyway. A TVS chosen by standoff voltage alone often clamps at one and a half to two times that voltage.

Example. On B200A the VBUS TVS D1605 has the value SMF5V0A but the symbol SMF22A. The 5 V part clamps around 9 V, acceptable for the 5 V-only input; the 22 V part only starts to conduct above its 22 V standoff, so the 5 V parts on VBUS behind it would see no protection at all.

How to check. For each TVS, take its clamping voltage at the specified surge current from the part data and the lowest absolute maximum of the pins on its net (NET-7); report when the clamp is above it, and value/symbol disagreements as BOM-12.

Fix. A TVS with a lower clamping voltage (a standoff just above the rail's maximum), series resistance between the TVS and the pin to share the surge, or a protected IC with a higher rating.

References. Wikipedia, Transient-voltage-suppression diode (en.wikipedia.org/wiki/Transient-voltage-suppression_diode); B200A schematic review notes (D1605 value vs symbol).