RATE-16 Ceramic capacitor DC-bias derating ignored

Severity Status Implementation
warning planned mid, depends on CFG-5, RPT-1

Looks at. The capacitor's working voltage, its capacitance vs DC bias curve (per MPN), the capacitance the circuit needs.

What it catches. A class 2 ceramic capacitor (X5R, X7R, Y5V) whose effective capacitance at the working voltage is below what the circuit needs, because its nominal value was taken at face value.

Why it matters. Class 2 dielectrics lose capacitance with DC bias, the more so the smaller the package and the closer the working voltage is to the rating: drops to −80 % are possible. A regulator output that needs 10 µF for stability gets 2-3 µF and oscillates; a decoupling bank sized by nominal values is a fraction of what was planned. The datasheet front page does not show it; the vendor's bias curve does.

Example. A 10 µF 6.3 V X5R 0402 on a 5 V rail as an LDO's output capacitor: at 5 V such parts typically keep a small fraction of their nominal value, so the LDO sees far less than the minimum capacitance in its datasheet. A 10 µF 10 V or 16 V part in 0603 or 0805 keeps much more.

How to check. For each class 2 ceramic, take its working voltage (rail) and the bias curve from the part data (vendors publish them per MPN); compute the effective capacitance; compare it with requirements where they are known (regulator minimum output capacitance, RPT-1 totals per rail).

Fix. A higher voltage rating or a larger package for the same value, more capacitors, or a C0G or film part where the value matters.

References. Wikipedia, Ceramic capacitor "Voltage dependence of capacitance"; MT-101 (Analog Devices, Decoupling Techniques) on ceramic capacitor choice (analog.com/.../MT-101.pdf).