RATE-15 Inductor saturation current below the converter's peak current

Severity Status Implementation
error runs in better_erc mid, depends on CFG-2, CFG-9, RPT-3

Data it needs: graph, part classes, parts snapshot.

Looks at. Input range, output voltage and current, switching frequency, inductance, the inductor's saturation current.

What it catches. A switching converter's inductor whose saturation current is below the peak current it must carry: the maximum output current plus half the ripple, at the maximum input voltage.

Why it matters. A saturated inductor loses its inductance, the current rises steeply within one cycle, the converter hits its current limit or the switch fails; at best the output collapses at full load. The inductor's "rated current" (thermal) and "saturation current" are different numbers, and the smaller one counts.

Example. A TPS62130 buck from 12 V to 3.3 V at 3 A, 2.5 MHz, with 1 µH: per SLVA477 the duty cycle is 3.3 / (12 × 0.9) ≈ 0.31, the ripple ΔIL = (12 − 3.3) × 0.31 / (2.5 MHz × 1 µH) ≈ 1.06 A, and the peak 3 + 0.53 ≈ 3.5 A. An inductor with a 3 A saturation current saturates at full load.

How to check. Find the converter's input and output rails, output current (project), switching frequency (part data) and inductor value; compute the peak per SLVA477 equations 1, 2 and 4; compare with the inductor's saturation current from the MPN (RPT-3 reports the same numbers).

better_erc (erc_checks/src/rate/rate_15.rs) takes the peak from the inductor's Ipeak field and asks each MPN's saturation current to be at least derating.inductor_isat (1.3) times it; the peak computed from the converter (RPT-3) is not built yet. Each MPN field (Mpn1, Mpn2, ...) of a fitted part is judged on its own against the facts of the parts snapshot (parts.lock.toml). A miss is one finding per part and MPN field (item C4 Mpn2) naming the margin, with the hash of the inputs it rests on (the working value and how it is known, the MPN's rating, the derating factor) for a waiver. A rating the snapshot lacks is never a pass: the part gets one info finding naming each MPN and fact not checked. A part whose stress is not known is not judged.

Fix. An inductor with saturation current above the peak with margin (or above the converter's switch current limit, which also covers faults), or a larger inductance to reduce the ripple.

References. SLVA477 §2 (maximum switch current, equations 1-4), §3 (inductor selection); TPS6213x datasheet (SLVSAG7F) (ti.com/lit/ds/symlink/tps62130); Wikipedia, Saturation (magnetic) (en.wikipedia.org/wiki/Saturation_(magnetic)).

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only RATE-15 reports on it.

rate-15_inductor_saturation

The test schematic rate-15_inductor_saturation The test schematic rate-15_inductor_saturation

  error      RATE-15 #st8   L1 Mpn1 DFE322520F-1R0M: 3 A rated, 3.5 A peak (Ipeak field), 0.86× < 1.3×
                            part L1, item L1 Mpn1
                            peak A = 3.5 A (Ipeak field) (sch rate-15_inductor_saturation.kicad_sch)
                            Mpn1.saturation_current = 3 (partdb parts.lock.toml DFE322520F-1R0M saturation_current (manual))
                            derating.inductor_isat = 1.3 (derived default derating.inductor_isat)
                            fix: an inductor whose saturation current is above the peak with margin, or more inductance for less ripple
                            input in1:688776e74bc85095