RATE-17 Electrolytic or tantalum without derating¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-5, CFG-5 |
Looks at. Rail voltage and source impedance, the capacitor's technology and rating.
What it catches. Aluminium electrolytic or tantalum capacitors run close to their rated voltage, and in particular solid tantalum capacitors without the customary 50 % voltage derating, or placed on a low-impedance rail (a battery, a strong supply) with no resistance to limit the inrush current.
Why it matters. Solid tantalum capacitors fail short, and the failure is often a fire: a defect in the dielectric heats under current, and on a low-impedance rail the current is limited by nothing. The industry's long-standing rule is to run them at no more than half their rated voltage; KYOCERA AVX's paper allows 80 % only with lower MTBF and higher leakage, and recommends limiting the surge current across low-impedance sources. Aluminium electrolytics fail more gently but age faster near their rating and at high temperature.
Example. A 16 V tantalum on a 12 V battery rail: 75 % of rating on a source that can deliver hundreds of amps into a short. The 50 % rule asks for a 25 V part (or a polymer or ceramic part instead).
How to check. Recognise the technology from the MPN (or value field, TANT), take the rail's maximum voltage and report ratings below 2× the rail for solid tantalum (a configurable ratio) and close margins for electrolytics; flag tantalums directly on battery or connector inputs without series resistance.
Fix. Double the voltage rating, use polymer tantalum or ceramic capacitors, or add series resistance or a soft-start FET in front of tantalums on low-impedance sources.
References. AVX derating (abstract: "a minimum of 50% voltage derating should be applied"; conclusion on 80 % use and low impedance sources); Wikipedia, Tantalum capacitor "Rated and category voltage" and "Surge voltage" (en.wikipedia.org/wiki/Tantalum_capacitor).