RAIL-11 Feedback divider sensing the wrong node¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-5, NET-7 |
Looks at. FB pin, the divider's top node, series parts on the rail.
What it catches. A feedback divider whose top is connected before a ferrite, filter, current shunt or switch, so the regulated voltage is not the one the load sees; or a top on a different net than the regulator's output.
Why it matters. Everything between the sense point and the load drops voltage with current: a ferrite's DCR, a shunt, a load switch's Rds(on). At full load the load sees less than the nominal, and a filter inside the loop can make the regulator unstable.
Example. A 1.0 V FPGA core buck sensing before a 0.1 Ω ferrite: at 2 A the core sees 0.8 V, below its 0.95 V minimum.
How to check. Follow FB's top resistor to its net; if that net reaches the load rail only through a series part (NET-5 ties), report it with the part's resistance where known.
Fix. Sense at the load (after the filter), with the datasheet's guidance for filters inside the loop, or take the ferrite out of the high-current path (DEC-9).