Skip to content

RAIL-24 Regulator EN pin floating on a part without an internal pull

Severity Status Implementation
error planned mid, depends on NET-7, NET-9

Looks at. EN pin role, whether the part pulls it internally.

What it catches. A regulator or load switch EN pin on a single-pin net, or driven only by a GPIO that is high-impedance at reset with no external pull, on a part without a documented internal pull.

Why it matters. A floating CMOS EN picks up whatever couples into it: the regulator starts on some boards, not on others, or turns on when a finger comes near. Driven by a GPIO that is an input at reset, the rail's state during boot is undefined.

Example. The RT5760: "Do not leave this pin floating". The AOZ1375DI: "The EN pin must be driven to a logic high or logic low state to guarantee operation". B153A does it right: the AOZ1375's EN on PA6 has a 10K pull-down R601, so plug VBUS is off at reset.

How to check. EN pins (NET-7) on single-pin nets, or on nets with only a tristate-at-reset driver and no resistor to a rail (NET-9); exempt parts whose data gives an internal pull.

Fix. Tie EN to its rail (within RAIL-15), or a pull to the state wanted at reset.

References. RT5760 pin description (EN); AOZ1375DI Detailed Description, "Enable"; B153A review notes §3.