Skip to content

RAIL-21 Total output capacitance outside the stable range after DC-bias derating

Severity Status Implementation
warning planned mid, depends on NET-7, RPT-1

Looks at. Capacitors per rail with case, voltage rating and dielectric, regulator limits.

What it catches. A regulator whose output capacitance, summed over the rail and derated for DC bias, falls outside the range the datasheet gives for stability, or is more than its soft start and current limit can charge.

Why it matters. Class II ceramics lose capacitance with applied voltage: a 10 µF 0603 X5R at 5 V is roughly 4 µF, a Y5V far less. The design "has 22 µF" on paper and is at the edge of stability in reality. At the other end, every downstream decoupling capacitor adds to the regulator's output: a rail with 500 µF on it may never finish soft start before the current limit or the hiccup timer kicks in.

Example. An LT3080 at 5 V with a 16 V 10 µF Y5V as its only output capacitor: 1-2 µF effective, below its 2.2 µF minimum. On the high side, a 1 A buck with 470 µF of downstream bulk and 1 ms soft start needs 1.55 A (470 µF × 3.3 V / 1 ms) on top of the load.

How to check. RPT-1 (capacitance per net derated at working voltage, from MPN or case and rating), compared with the datasheet's minimum and maximum output capacitance; C · Vout / tSS against the current limit.

Fix. Larger case or higher-rated capacitors, X7R over Y5V; a longer soft start or a load switch to separate the bulk from the regulator.

References. LT3080 "Stability and Output Capacitance" (Figure 2, Figure 3); SLVA477 §7 (output capacitor selection); AP64060 "Output Capacitor".