Skip to content

RAIL-8 LDO output capacitor not what the part needs for stability

Severity Status Implementation
warning planned mid, depends on NET-7, RPT-1

Looks at. The LDO's output capacitor requirement, capacitor values and dielectric.

What it catches. An LDO whose output capacitance is below the datasheet minimum, or of the wrong kind: ceramic on an old part that needs some ESR to be stable, or a high-ESR electrolytic on a part designed for ceramics.

Why it matters. An LDO is a feedback loop; the output capacitor and its ESR place a pole and a zero in it. Out of the stable window it oscillates, sometimes only at some load or temperature, and the "noisy rail" is found months later.

Example. A TLV702 needs 1 µF ceramic on OUT (stable down to 0.1 µF effective). An LT3080 wants at least 2.2 µF with ESR ≤ 0.5 Ω; fitted with a 16 V 10 µF Y5V on a 5 V output, the effective value can drop to 1-2 µF.

How to check. Sum the capacitors on the LDO output net (RPT-1), derated per dielectric and voltage, compare with the part's minimum and ESR window.

Fix. Follow the datasheet's capacitor section; X5R/X7R ceramics for modern LDOs, an ESR-tolerant part or a small series resistor where the datasheet asks for ESR.

References. SLVA115 §1; SLVA079 §10 (instability of the LDO, Figure 12 stable range of CSR); TLV702 §8.2.2.1; LT3080 "Stability and Output Capacitance".