RAIL-16 Soft-start, compensation or timing pins without the required parts¶
| Severity | Status | Implementation |
|---|---|---|
| error | planned | mid, depends on NET-7 |
Looks at. Pin roles (SS, COMP, RT, CT) and what the datasheet requires on them.
What it catches. A regulator's SS, COMP, RT or CT pin left open or tied where the datasheet requires a capacitor, an RC network or a resistor.
Why it matters. An external-compensation buck with COMP open has no loop compensation: it oscillates or latches off. RT open sets no frequency (some parts default, others do not start). SS open starts with no soft start, so the inrush trips the source's current limit (SEQ-6).
Example. The AOZ1375DI on B153A has its SS pin with 1 nF; drawn from a template that left SS open, the switch would turn on hard into the plug's capacitance.
How to check. For each pin with one of these roles (NET-7), the parts the datasheet requires on it (a capacitor to ground, a resistor to ground, an RC to ground); a single-pin net is the clearest miss.
Fix. Add the parts from the datasheet's typical application, with values from its design procedure.
References. AOZ1375DI pin description (SS) and Detailed Description; SLVA477 §1 (necessary parameters of the power stage).