RAIL-12 Conversion ratio vs switching frequency¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-7, CFG-2 |
Looks at. Vin range, Vout, fSW, minimum on-time and maximum duty cycle.
What it catches. A buck whose duty cycle D ≈ Vout / Vin needs an on-time D / fSW below the part's minimum on-time at the highest input, or a duty cycle above its maximum at the lowest input (unless it has a 100 % mode).
Why it matters. Below the minimum on-time the converter cannot make the pulse it needs: it skips pulses, the ripple grows and the frequency drops into audible or EMI-sensitive bands. Above the maximum duty cycle it falls out of regulation.
Example. The AP64060 on B153A runs at 2 MHz with a 60 ns minimum on-time; 3.3 V out needs D = 0.165 at 20 V (82 ns, fine) but only 41 ns at the 40 V on the sheet note: above about 27 V input the part cannot hold its frequency. B153A's input stops at 20 V (USB PD), so the board is safe; a 24 V industrial input would not be. A 24 V to 1 V buck at 2 MHz needs 21 ns, below almost every part.
How to check. From Vin range (CFG-2), Vout and fSW, compute the on-time at Vin(max) and duty cycle at Vin(min); compare with tON_MIN and D(max) from the part data.
Fix. A lower-frequency sibling (AP64062, 1.2 MHz), two stages, or a part with a smaller minimum on-time; on the low end a part with 100 % duty cycle (the RT5760 has it).
References. SLVA477 §2 (Equation 1, duty cycle); AP64060 Electrical Characteristics (tON_MIN, fSW); RT5760 "Maximum Duty Cycle Operation"; Wikipedia, Buck converter.