RAIL-6 Current-limit resistor vs the limit the design states

Severity Status Implementation
warning planned hard, depends on NET-7, CFG-2

Looks at. The part's limit formula, the resistor value, the stated limit.

What it catches. An ILIM, ISET or RLIM resistor whose value, put into the datasheet formula, gives a limit different from the one the sheet note or the project states, or outside the range the datasheet guarantees.

Why it matters. The limit is what protects the cable, the connector and the far board; a factor of two off means either nuisance trips at normal load or no protection at all. Formulas are per part and often hold only for a stated sense resistor or direction.

Example. B153A U601 AOZ1375DI with R605 14K5 and a 5 mΩ shunt; the sheet says "Ilim = 160/Rlim[kΩ] = 5.5 A". The datasheet formula is 160 / RLIM for a 10 mΩ RSENSE: 160 / 14.5 = 11 A, already outside the 1-6 A range the datasheet guarantees, before the 5 mΩ shunt is taken into account. It also limits one direction only: "no current limiting function when configured as sink".

How to check. Find the resistor on the limit pin, evaluate the part's formula (with its sense resistor), compare with the stated limit (CFG-2, or the sheet note) and the datasheet's valid range.

Fix. Recompute R from the formula for the actual shunt; when the part's range does not reach the wanted limit, change the shunt or the part.

References. AOZ1375DI Detailed Description, "Programmable Over-Current Protection (OCP)" and Figure 20; B153A review notes §3; B153 rev B change list.