RAIL-3 Net name carries a voltage that is wrong¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-5, RPT-6 |
Looks at. Voltage parsed from the net name, the rail's real voltage.
What it catches. A net whose name says one voltage (+1V8_LDO, _3V3, 5V0_) while the source that feeds it makes another: a fixed regulator, a divider, a connector pin with a stated voltage.
Why it matters. People and firmware trust the name. A rail named 1.8 V that is 3.3 V gets connected to 1.8 V parts in the next revision, and the test plan measures against the wrong value. When the name is right and the part is wrong, the same comparison finds the real bug (RAIL-4).
Example. On B200A +1V8_LDO sits at about 3.2 V (a 3.3 V LDO in dropout from 3.32 V); the firmware offered "1.8 V" IO levels that were really 3.2 V until the review caught it.
How to check. Parse the voltage from the name (NET-5 already does), take the source's voltage from RAIL-2 or RAIL-4, report a difference beyond the rail tolerance.
Fix. Fix the part (usually) or rename the net; never both without deciding which was meant.
References. B200A review notes §0, B200 rev B change list.