Skip to content

RAIL-18 Two regulator outputs tied together

Severity Status Implementation
error runs in better_erc easy, depends on NET-5

Data it needs: graph, part classes, rails.

Looks at. Power output pins on one net, parts that allow paralleling.

What it catches. Two regulator outputs (LDO, DC-DC, a module) on the same net without ORing, ballast or a part designed for paralleling.

Why it matters. Two regulators never agree on the voltage: the higher one carries all the load while the other's loop drives its output to zero current, or one sinks current from the other (a synchronous buck can sink), and current sharing is anyone's guess. Sometimes it is a leftover of two footprint options both populated.

Example. Two TLV70233 in parallel "for 600 mA": the one with the higher output takes nearly all the load and current-limits, the other idles. The LT3080 is built for paralleling: SET pins tied together and a few milliohms of trace as ballast to share the current.

How to check. Count power-output pins (regulator OUT/VOUT/SW-after-inductor) per rail (NET-5); more than one is a finding unless the part data marks the part as parallel-capable and ballast is present.

Fix. One regulator of the needed current, a part made for paralleling with ballast, or ORing diodes / ideal-diode controllers when two sources are intended (PIN-12).

References. LT3080 "Paralleling Devices" (Figure 4, Table 1); KiCad ERC "Power pins and power flags" (why two power outputs on one net are already a pin conflict).

Test schematics

Each schematic below is in test_schematics/sources. The block under it is what berc check --only RAIL-18 reports on it.

rail-18_parallel_regulators

The test schematic rail-18_parallel_regulators The test schematic rail-18_parallel_regulators

  error      RAIL-18 #vxe   the outputs of U3 and U4 all drive +1V8: parallel regulators fight, the higher one takes the load
                            net +1V8, part U3, part U4
                            fix: one regulator for the current needed, a part made for paralleling with ballast, or ORing diodes when two sources are meant (PIN-12)
  error      RAIL-18 #m5g   the outputs of U1 and U2 all drive +3V3: parallel regulators fight, the higher one takes the load
                            net +3V3, part U1, part U2
                            fix: one regulator for the current needed, a part made for paralleling with ballast, or ORing diodes when two sources are meant (PIN-12)