RAIL-25 Input range below the regulator's minimum Vin or UVLO¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | mid, depends on NET-5, NET-7, CFG-2 |
Looks at. Input voltage range, the regulator's Vin(min) and UVLO.
What it catches. A regulator whose input, at the low end of its range (a discharged battery, a sagging cable, the far end of a diode-OR), drops below the part's minimum operating Vin or its UVLO threshold.
Why it matters. Below UVLO the part turns off; around it, it may cycle on and off as the load pulls the input down and releases it. A 4.5 V-minimum buck on a 3-cell alkaline pack (3.0-4.8 V) runs only while the batteries are fresh.
Example. B153A's AP64060 (4.5-40 V, UVLO 3.8 V falling) runs from VBUS through a 1N5819W diode-OR: USB's 4.75 V VBUS minus a Schottky drop at load is near 4.3-4.4 V, below the 4.5 V the datasheet specifies though above UVLO, so the part keeps running out of its specified range on a weak port.
How to check. Vin(min) of the input rail (CFG-2, minus series drops of diodes and switches on the way) against the part's minimum Vin and UVLO (NET-7).
Fix. A part with a lower minimum Vin, a buck-boost, an ideal diode instead of a Schottky in the OR, or an adjusted UVLO divider on EN where the source should be cut off (PIN-16).
References. AP64060 "Adjusting Undervoltage Lockout (UVLO)" and Electrical Characteristics; TLV702 §7.3.4; B153A review notes §2.