RAIL-22 Inductor value outside the datasheet range

Severity Status Implementation
warning planned mid, depends on NET-7, RPT-3

Looks at. Inductor value and ratings, fSW, Vin, Vout, load current.

What it catches. A switching regulator's inductor whose value is far from the one the datasheet's equation or table gives for the switching frequency, voltages and current; or whose saturation current is below the peak.

Why it matters. Too small: the ripple current is large, peak current reaches the switch limit before the rated load, and the output ripple grows. Too large: slow transient response, and for current-mode parts with internal slope compensation, subharmonic oscillation. A saturating inductor is a short at the peak.

Example. The AP64060's Table 1 gives 8.2 µH at 3.3 V for the 2 MHz AP64060 and 10 µH for the 1.2 MHz AP64062; B153A fits 10 µH on the AP64060, the value of the slower sibling (in range here, but the kind of copy RAIL-23 is about). B200A's RT5760 at 2.2 MHz uses 1 µH.

How to check. L = Vout · (Vin − Vout) / (Vin · ΔIL · fSW) with ΔIL of 20-40 % of the load, against the fitted value; peak current Iout + ΔIL / 2 against the inductor's Isat (RPT-3).

Fix. The datasheet's recommended value; an inductor with Isat above the switch current limit.

References. SLVA477 §3 (inductor selection); SLVA372 §3; AP64060 "Inductor" (Eq. 5) and Table 1.