Skip to content

RAIL-4 Fixed-output regulator whose MPN voltage differs from the net it feeds

Severity Status Implementation
error planned mid, depends on NET-5, NET-7

Looks at. Output voltage decoded from the MPN, net voltage.

What it catches. A fixed-output regulator whose part number encodes a voltage (TLV70233 = 3.3 V, TLV70218 = 1.8 V, TLV74311 = 1.1 V) different from the voltage of the net on its output.

Why it matters. The symbol is usually shared across the voltage options and the value field is copied from the BOM, so the sheet reads "1V8" next to a 3.3 V part and nothing looks wrong. Every part on the rail gets the wrong supply.

Example. The same miss on two boards: B153A U802 and B200A U1602 are TLV70233 (3.3 V) on +1V8_LDO. On B200A every "1.8 V" IO and I2C level was ~3.2 V; both rev B change lists swap to a TLV70218.

How to check. Decode the voltage from the MPN with the family's nomenclature (TLV702xx: "XX is nominal output voltage"), compare with the output net's voltage (NET-5), and check every MPN option of the BOM line, not only the first.

Fix. Order the right voltage option, and put the voltage in the symbol's value so the sheet shows it.

References. TLV702 §11.1.2 Device Nomenclature; B153 and B200 rev B change lists.