RAIL-13 Boost converter output not isolated when disabled¶
| Severity | Status | Implementation |
|---|---|---|
| warning | planned | hard, depends on NET-6, NET-7, NET-8 |
Looks at. Boost topology, part's disconnect feature, power states.
What it catches. A boost whose output is meant to be off in some power state, built with a part (or a discrete inductor and diode) that leaves a DC path from input to output when disabled.
Why it matters. In a classic boost the inductor and the rectifier are a straight path from Vin to Vout: "off" is Vin minus a diode drop. A 5 V USB output from a battery boost stays at 3.5 V when off, a sensor rail meant to cut power keeps it, and the "disabled" load drains the battery.
Example. A 3.7 V cell boosted to 5 V for a USB port with an asynchronous boost and a Schottky: with EN low the port still has 3.4 V and the attached device draws the battery flat. A boost with true load disconnect (TPS61099 class: the rectifying PMOS turns fully off) avoids it.
How to check. Recognise the boost (inductor from the input to the SW node, rectifier to the output, NET-6); look up whether the part disconnects; flag it when the output rail is off in some power state (NET-8).
Fix. A boost with load disconnect, or a load switch after the boost.
References. SLVA372 §1 (topology); TPS61099 §7.1, §7.3.3; Wikipedia, Boost converter.